View All Tenders

Online Submitted Tender

Organization Name

National Transmission and Despatch Company

Address Director Media NTDC, Room No 63 Wapda House
City Lahore
Tel No. 042-99204881
Fax No. 042-99204882
Receipt No 161467
Tender No HV & SC LAB. NTDC, RAWAT, ISLAMABAD
Description NATIONAL TRANSMISSION & DESPATCH COMPANY LIMITED (NTDC). NOTICE FOR INVITING TENDER FOR PROCUREMENT OF DIFFERENT TESTING EQUIPMENT FOR HV & SC LAB. NTDC, RAWAT, ISLAMABAD Tender Notice No: OL-03/2021-22 This office invites sealed technical & financial bids (USA, European & Japanese make) from renowned manufacturers, suppliers or authorized distributers registered with Income Tax and Sales Tax departments and who are on Active Taxpayers List of the Federal Board of Revenue, for the procurement of: S. # Specification Quantity Lot 1. Automatic Kinematic Viscosity Bath: (including all standard & optional accessories) conforming to the specifications of: The complete unit must be:  In compliance with ASTM D-445 & ISO-3104.  Temperature controlled with adjustable temperature options (ambient-40?C)  Equipped with sensitive flow detection system The unit shall mimic all the physical conditions, operations & processes of the manual apparatus as described in ASTM D-445. The price of all optional accessories shall be included in the bid price. 01 Lot. 2 Oxidation Stability Test Set (12 Unit) Along-With Complete Accessories as per IEC-61125: Heating Arrangement (01No.): Thermostatically controlled Aluminum Alloy Block Heater or Oil Bath capable to maintain the insulating liquid in 12 Nos. of oxidation tubes at desired Temperature of 100 0C and 120 0C. Test Vessels (24 Nos.): Test tubes of borosilicate/neutral glass with a 24/29 ground joint of the following dimensions:  Overall length 210 ? 2mm  External diameter 26 ? 0.5mm  Wall thickness 01.4 ? 0.2mm  Height of the Head 28 ? 02mm  Air Inlet Tube External diameter 05.0 ? 0.4mm  Wall thickness 00.8 ? 0.1mm Absorption tubes (24 Nos.): Identical to the test vessels. Silicon rubber sleevings for connecting test vessels and absorption tubes. Porcelain crucibles (50ml) 06 Nos. Soap bubble flow meter 01 No. Timer 01 No. Certified Brand New air filled cylinder (02 Nos.): Each with safety valves and multistage pressure regulator Burets of 10ml with graduation of 0.01ml (06 Nos.) Thermometer (98 0C ? 150 0C) (01 No.) Erlenmeyer flasks (500ml) with ground glass stopper (06 Nos.) Copper catalyst coil Pre-formed (500 Nos.) Membrane filter of 8?m The price of all standard/ optional & above mentioned accessories shall be included in the bid price. 01 Lot. 3 3 Phase Precision Power Analyzer/METER along-with complete accessories conforming to following specifications: 01 Supply Voltage/Frequency 100 to 240 VAC/ 50 Hz Input Voltage Range: 0.5 to 1000V ( Vpeak= 2 x voltage range) Current Input Range (Direct or through shunt): (If direct current input is less than 40 A, the offer shall be made with optional shunt up to 100 A) 1mA to 40A or above Sampling Rate: 300 kHz or above Bandwidth: Up to 3 MHz Basic Accuracy 0.05% of Reading Basic power accuracy (50/60 Hz): 0.07% of Reading Fast Fourier Transformation (FFT) up to 30th harmonics Display Large and bright color display Display Resolution: Min. 5 digits o Display Format: Numeric Values, Waveforms, Trends, Bar graphs, Vectors. o Minimum 3 input channels (3-Phase) or above o Auto ranging facility. o Input for user defined functions. o Store function: 50 ms data storing interval. o 03 MB Internal Memory. o Instant Saving option for Numeric Values, Waveforms, Trends, Bar graphs, Vectors. o Built-In Printer. o 50 ms Data Updating Intervals. o Interface: GP-IB, Ethernet, RS-232 and USB. o USB Port for data communication with PC. o FFT (Fast Fourier transform) analysis and waveform sampling data saving. o IEC61000-3-2 and IEC61000-3-12: Harmonic measurement up to 30th Order. o IEC61000-3-3 and IEC61000-3-11: Voltage fluctuation / flicker measurement. o IEC61000-4-15 Ed2.0 (Support Flicker meter standard). o The test set must include all accessories, cables of appropriate length, shunts, clamps and spares etc. required during measurement of Load/No-load losses of Power/Distribution Transformers and other power system equipment o The equipment shall be capable of taking measurement through external measurement CTs. 1. Bidding documents, containing detailed terms and conditions, etc. are available at the office of Chief Engineer (HV & SC) Lab. NTDC, Rawat, Islamabad. 2. Price of the bidding documents is PKR 2000/- (non-refundable). 3. Bidding documents can also be downloaded from www.ntdc.com.pk free of cost for working only. 4. The bids, prepared in accordance with the instructions in the bidding documents, must reach the office of Chief Engineer (HV & SC) Lab. NTDC, Chakbeli Road Rawat, Islamabad on or before 13.04.2022 at 1100 Hrs. 5. Bids will be opened on the same day at 1130 Hrs. 6. Bid shall remain valid for 60-days from the bid opening date and must accompany Bid Guarantee/ CDR not less than 2% of the quoted bid price, valid for 100 days issued by any scheduled Bank of Pakistan on specified Proforma along with Sales Tax Registration Certificate. 7. Mail or conditional tender or tender without Bid Guarantee will not be accepted. 8. NTDC reserves its rights regarding rejection of tenders as defined in clause-33 (1) of PPRA Rules-2004. 9. This advertisement is also available on PPRA website at www.ppra.org.pk. 10. All the relevant information can be obtained from the office of Chief Engineer (HV & SC) Lab. NTDC, Rawat, Islamabad on the following contacts before the tender opening date. Tel No. 051-4262306, 4262309 Email; cehvc@ntdc.com.pk CHIEF ENGINEER HIGH VOLTAGE & SHORT CIRCUIT LAB NTDC RAWAT, ISLAMABAD
Remarks
Advertisement Date 28/3/2022
Closing Date 13/4/2022
Closing Time 11:00:00 AM
Opening Time 11:30:00 AM
Tender Documents
Estimated Cost
Tender Nature National
Earnest Money
Bid Validity
Bid/Tender Document Cost
Remarks